Ubuntu software RAID is Linux MD, managed by mdadm. You can create an array in the Ubuntu Server installer or build one from the command line for finer control. Choose the RAID level first, back up anything important, verify every disk by stable identifiers, then create, format, mount and monitor the array. RAID improves availability or combines disks; it does not replace an independent backup.
Antihost offers Linux VPS plans with full root access, unlimited traffic on a 1 Gbps port and a 14-day free trial.
What Ubuntu RAID is—and what it is not
RAID (Redundant Array of Independent Disks) makes multiple physical drives operate as one logical storage device. Ubuntu’s software implementation is Linux MD, with mdadm providing creation, assembly, inspection and repair operations. The Ubuntu Server installer can configure common arrays during installation; the command-line interface is preferable when you need exact metadata, partitioning or boot decisions.
As an Amazon Associate I earn from qualifying purchases.
Outdated Drivers Are Slowing You Down
One free scan finds every outdated or missing driver and matches the right update for your exact hardware.Free scan · exact hardware matchWindows Errors? Fix Them Before They Spread
Repair common Windows errors and clear accumulated junk for a smoother, more stable PC - no reinstall needed.Free scan · no reinstallRAID protects against particular disk failures, depending on its level. It does not protect against accidental deletion, filesystem corruption, malware, theft, fire or an administrator formatting the wrong device. Keep a separate, tested backup before changing partition tables or creating an array. A backup should be restorable without the RAID host being available.
Choose the RAID level before touching a disk
The level determines minimum device count, usable capacity, failure tolerance and how exposed the array is while rebuilding. There is no universal performance ranking: results depend on the workload, controller path, filesystem, queue depth and drives.
#1 Best Overall
- Compatible with: LSI 9300-8i; Controller: LSI/Broadcom SAS3008 (12Gb/s SAS)
- Firmware (FW): HBA IT Mode (Non-RAID); Data Transfer Rate: up to 12Gbps SAS, SATA 6Gbps
- Host Interface: PCIe 3.0 x8; Internal Connectors: 2× Mini-SAS HD SFF-8643. --Direct attach up to 8 drives, and expand via external SAS Expander for large arrays
- PERFECT FOR: ZFS, FreeNAS/TrueNAS, unRAID, Proxmox, ESXi home-lab & NAS storage
- Packing List: HBA Card ×1; 2× SFF-8643 to 4× SATA cables (8× SATA ends). --Cables in box are for SATA drives. They are not compatible with SAS drives. To connect SAS drives, use SFF-8643 to 8482 SAS cables (sold separately) or our matched HBA + cable kit.
| Level | Minimum devices | Usable capacity | Failed-device tolerance | Workload behavior | Rebuild exposure | Boot suitability |
|---|---|---|---|---|---|---|
| RAID0 (striping) | 2 | Approximately the sum of member capacities, limited by the smallest member in each stripe | None; one failed member makes the array unavailable | Parallel I/O can help throughput, but every file spans the set and has no redundancy | There is no redundant rebuild; restore from backup after a failure | Not suitable when you need boot resilience |
| RAID1 (mirroring) | 2 | Approximately the capacity of one member | One member in a two-device mirror | Reads may be served by either copy; writes must reach the mirror | Replacing a member copies all required data and leaves the mirror degraded until complete | The stock Ubuntu bootloader supports softRAID level 1 for /boot |
| RAID5 (striping with distributed parity) | 3 | Approximately the sum of all but one member’s capacity | One member | Parity work affects writes; suitability depends on workload and device type | During recovery, the array has no remaining single-device margin | The stock Ubuntu bootloader cannot use a softRAID level other than RAID1 for /boot |
| RAID6 (striping with dual parity) | 4 | Approximately the sum of all but two members’ capacity | Two members | Dual-parity calculations add write overhead but provide more failure tolerance | Recovery can be lengthy and performance-sensitive while two-device tolerance is being restored | The stock Ubuntu bootloader cannot use a softRAID level other than RAID1 for /boot |
The Ubuntu guide lists two drives for RAID0 and RAID1, three for RAID5 and four for RAID6. A larger set can change usable capacity, recovery time and operational risk, so size the array for the failure policy you actually need rather than choosing a level from capacity alone.
Prepare disks and a recovery plan
Back up and document the host
- Make and test an independent backup before repartitioning or creating the array.
- Record the intended operating-system disk, each prospective member and any disk that must remain untouched.
- Plan where boot, swap, metadata and data filesystems will live. Do not consume every sector if your boot design or future replacement strategy needs reserved space.
- Have console or out-of-band access available. A storage mistake can make a remote server unbootable.
Identify disks by facts, not by letter order
Linux device names such as /dev/sda and /dev/sdb are not a safe identity scheme: enumeration can change after reboot or hardware changes. Before selecting members, inspect size, type, filesystem and mount points:
What’s actually slowing this PC down?
Pick the symptom - the matching free tool is one click away.
lsblk -o NAME,SIZE,TYPE,FSTYPE,MOUNTPOINTS
blkid
Confirm the serial number or another stable identifier in your hardware and operating-system inventory. Re-run the checks immediately before a destructive command. Never paste an example containing /dev/sdX without replacing it with the verified partition path for this host.
Partition members consistently
Create equivalent partitions on each member disk, with matching or deliberately planned sizes. If one disk is smaller, an array may be limited to the smallest corresponding partition. Keep the partition layout identical enough that a replacement disk can receive the same member partition, and leave room for any separate boot or swap arrangement. The installer and mdadm operate on partitions as well as whole disks; using partitions makes the intended boundaries explicit.
Create an array in the Ubuntu Server installer
An Ubuntu Server installation ISO includes software-RAID options. This path is convenient when the machine is being installed from scratch and you want the installer to create filesystems and mount points at the same time.
- Boot the Ubuntu Server installer and proceed to the storage or partitioning screen.
- Choose manual partitioning so you can create equivalent partitions on every intended member disk.
- Select Configure Software RAID and confirm the action when prompted.
- Choose Create new MD drive.
- Select the RAID type: RAID0, RAID1, RAID5 or RAID6. Ensure the number of selected partitions meets the level’s minimum requirement.
- Set the number of active devices and, if your design calls for it, spare devices.
- Select the member partitions. Check each disk’s size and identity rather than relying on its position in the list.
- Return to the storage layout and assign a filesystem and mount point to the resulting MD device. Keep boot-related filesystems on a design supported by your firmware and bootloader.
- Review the final layout, including disks that are not part of the array, then finish the installation.
The installer’s RAID configuration does not remove the need for backups or monitoring. After the first boot, verify that the array assembles and that synchronization has completed before placing important data on it.
The Tool Desk
Outbyte Driver Updater FREEFix the driver behind crashes, sound loss and screen glitchesFind Drivers →Outbyte PC Repair FREERepair Windows errors before they cause bigger problemsFix Now →Rank #2
Create a software RAID array with mdadm
Install the management tools
sudo apt install mdadm
On an existing system, stop services and unmount any partitions that will become members. Verify that the target partitions contain no data you need; mdadm --create initializes array metadata and the subsequent filesystem operation is destructive.
Create the array
The following is a pattern for a two-device mirror. Replace every placeholder with the actual, verified partition path and change the level and device count to match your plan:
sudo mdadm --create /dev/md0 --level=1 --raid-devices=2 /dev/<partition1> /dev/<partition2>
For RAID0, RAID5 or RAID6, use the corresponding --level and provide the required number of member partitions. Do not blindly reuse /dev/md0; an existing host may already use that name. Read the command output for warnings about metadata, devices or an existing filesystem before proceeding.
Watch initial synchronization
cat /proc/mdstat
sudo mdadm --detail /dev/md0
/proc/mdstat reports active arrays and synchronization or recovery progress. mdadm --detail shows the level, state, member devices, active and failed counts, and rebuild information. A healthy mirror commonly displays a status such as [UU]; a three-member healthy set may show [UUU]. A missing member appears as an underscore, for example [U_], and means the array is degraded.
Create a filesystem and mount it
sudo mkfs.ext4 /dev/md0
sudo mkdir -p /srv/raid
sudo mount /dev/md0 /srv/raid
Choose the filesystem and mount point for the workload. Formatting the assembled MD device, rather than an individual member partition, ensures the filesystem uses the array abstraction.
Make assembly and mounting persistent
An array that works only until reboot is not a finished configuration. Record the array definition in Ubuntu’s mdadm configuration, normally /etc/mdadm/mdadm.conf, using an ARRAY definition appropriate to the assembled device. The exact line should describe the array’s UUID and metadata as reported by mdadm --detail or an examine operation; do not copy an unrelated host’s UUID.
Rank #3
- LSI 9211-8I SAS2008 CHIP
- (LSI 9211-8i) FW: P20 IT Mode
- 6Gbps PCI E X8 2.0
- ZFS FreeNAS unRAID
- Packing List: HBA Card ×1,High and low bracket*1,2*SFF-8087-SATA Cable
Use the filesystem UUID or a filesystem label in /etc/fstab, not a potentially changing member path. Obtain the UUID with blkid, then create an entry for the mounted filesystem. Test the entry with a controlled unmount and mount, and check for errors before rebooting.
If the array is required during boot, ensure the initramfs includes the mdadm configuration. On Ubuntu this commonly means rebuilding the initramfs after editing the configuration:
Quick wins for a faster PC:
Repair Windows errors before they cause bigger problemsFix Now →Scan for outdated or missing drivers - takes under a minuteDriver Scan →sudo update-initramfs -u
Reboot during a maintenance window, confirm the array assembles automatically, and check the mount. A successful first assembly test is important evidence that the configuration is persistent; it is not a substitute for a backup.
Monitor health, synchronization and degraded states
Check immediately after creation
- Run
cat /proc/mdstatand note whether the array is resyncing, recovering, inactive or degraded. - Run
sudo mdadm --detail /dev/md0and verify the expected level, UUID, member count and device roles. - Confirm the filesystem is mounted on the intended directory and that applications can read and write expected data.
- Review system logs for device resets, I/O errors or assembly failures.
Keep watching during a rebuild
Synchronization can continue after the shell command returns. Monitor until the progress line disappears and the detail output reports all expected devices active. On a server, retain alerts and logs so a second failure or an interrupted recovery is noticed promptly. Rebuild exposure is the period in which a redundant array has less protection than intended; do not treat a degraded array as normal operating mode.
Reassemble an existing array
If an array was created previously but is not active, verify the member identities and use the documented scan operation:
sudo mdadm --assemble --scan
Do not force assembly merely to make a device appear. First determine whether the members belong to this array, whether metadata is current and whether another array has claimed one of the partitions.
Rank #4
- Part Number: 5FMY4
- 8GB Nonvolatile Cache
- Supports 12Gb/s SAS and 6Gb/s SATA
- RAID levels: 0, 1, 5, 6
- RAID spans: 10, 50, 60
Replace a failed RAID member safely
Confirm the failure
Start with the array, not with the disk’s position in the chassis:
sudo mdadm --detail /dev/md0
cat /proc/mdstat
lsblk -o NAME,SIZE,TYPE,FSTYPE,MOUNTPOINTS
blkid
Correlate the failed partition shown by mdadm with a physical serial number and with system logs. A transient cable or power problem can look like a disk failure; investigate it before removing hardware. Never remove a healthy member because its /dev/sdX letter changed.
Mark and remove the failed partition
After confirming the identity, mark the member failed and remove it from the active set. The operation syntax is:
sudo mdadm /dev/md0 --fail /dev/<failed-partition>
sudo mdadm /dev/md0 --remove /dev/<failed-partition>
Some arrays mark a device failed automatically. In that case, the explicit --fail step may already have been completed, but verify the state before issuing any command.
Prepare the replacement
Install a replacement with a compatible interface and at least the required usable size. Recreate the member partition with the same intentional boundaries as the surviving disk; a replacement that is nominally the same capacity can still be too small if its usable sector count differs. Re-run lsblk and blkid to make sure you are adding the new partition, not an existing filesystem or a partition from another array.
Add it and monitor recovery
sudo mdadm /dev/md0 --add /dev/<replacement-partition>
cat /proc/mdstat
sudo mdadm --detail /dev/md0
The array should enter recovery or resynchronization. Keep monitoring until every expected member is active and the status returns to a healthy marker such as [UU]. If the add operation is rejected, stop and inspect size, partition type, metadata and UUIDs rather than forcing the device.
Best Value
- 6-PORT SATA EXPANSION CARD: Adds 6 SATA III (6Gbps) drives to your desktop at once, turning one PCIe x4 slot into a 6-bay storage pool for unRAID, TrueNAS, ZFS, Proxmox or Windows Storage Spaces software RAID. Hardware RAID is not supported.
- 277MB/S ON EVERY PORT: PCIe 3.0 X2 upstream runs at 16GT/s, and each of the 6 SATA ports delivers up to 277MB/s, so large multi-drive transfers, media libraries and backup jobs finish fast with no bottleneck.
- NO DRIVER, WIDE COMPATIBILITY: Plug and play on Windows (except XP), Mac OS, Linux and NAS systems. Set SATA mode to AHCI in BIOS or UEFI before first install. This is a data storage HBA and does not boot an operating system.
- 6 BUILT-IN LED INDICATORS: A steady red LED means the drive is powered, a flashing LED means it is reading or writing, so you can check every SATA drive at a glance without opening the case.
- FITS X4/X8/X16 SLOTS, FULL KIT INCLUDED: Ships with 6 x SATA III cables (350mm/13.5in), a 1:5 SATA power splitter cable, and both a 12cm regular and an 8cm low-profile bracket for any PC or NAS case.
Design boot correctly
Boot storage has stricter requirements than an ordinary data mount. The Ubuntu Community Help Wiki warns: “the /boot filesystem cannot use any softRAID level other than 1 with the stock Ubuntu bootloader.” Therefore, a RAID5 or RAID6 data array should not be assumed to make /boot bootable.
A common resilient design is a separate RAID1 arrangement for boot-related partitions, with the data array using the level selected for the workload. Another design may keep boot outside the data array, but it must be validated for the target firmware, partition scheme and installer. Do not infer compatibility from the fact that Linux can assemble a data array after boot.
Recommended Free Tools
When the design requires boot from more than one disk, install boot code on every boot-capable disk. The Ubuntu guide provides grub-install examples for additional disks; adapt the device names to the actual machine and firmware mode. Test a controlled degraded boot only in a maintenance window, with a verified backup and a way to restore the original boot order.
Degraded operation and recovery decisions
An array can remain available while degraded, depending on its level and the nature of the failure. Availability is not the same as safety: RAID1, RAID5 and RAID6 have less redundancy until a replacement finishes rebuilding, while RAID0 has no degraded protection. Limit writes and nonessential maintenance during recovery when practical, but do not interrupt a healthy rebuild without a clear reason.
- If
mdadm --detailreports an unexpected number of devices, stop and identify whether the problem is a failed disk, a detached device, a cabling issue or an assembly problem. - If a replacement will not add, compare its partition size and metadata with a surviving member.
- If the array will not assemble, check the recorded UUID and member metadata before considering any force option.
- If the filesystem is damaged, use the backup and filesystem-specific recovery procedures; rebuilding RAID metadata does not repair filesystem corruption.
Ubuntu 24.04 LTS considerations
Ubuntu 24.04 LTS receives security maintenance for five years, through 31 May 2029. That support window does not remove the need to test kernel, firmware and storage changes on the particular server.
Ubuntu’s release notes warn that TPM-backed full-disk-encryption kernel constraints can make hardware such as the vmd module required for NVMe RAID unavailable in some configurations. If you are combining NVMe RAID with that encryption path, validate module availability and the complete boot sequence before enabling encryption on production data. A configuration that works with an unencrypted installer environment may fail when the encrypted initramfs must assemble the array.
Do these 3 things before closing this tab:
1Fix the driver behind crashes, sound loss and screen glitches2Repair Windows errors before they cause bigger problems3Scan for outdated or missing drivers - takes under a minuteQuick Recap
Operational checklist
- Backups are independent of the array and have been restored in a test.
- The RAID level matches the required capacity and failure tolerance.
- Every member partition was verified with
lsblk,blkidand, where possible, hardware serial information. - Boot, swap and data filesystems follow a deliberate layout;
/bootuses RAID1 if it is on softRAID with the stock Ubuntu bootloader. mdadm --detailand/proc/mdstatshow the expected level and members.- The filesystem is mounted by UUID or label in
/etc/fstab. /etc/mdadm/mdadm.confand the initramfs contain the information needed for assembly during boot.- A reboot test confirmed automatic assembly and mounting.
- Alerts and logs are monitored, and the failed-member replacement procedure is documented for this host.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.